Sun Microsystems Sun StorEdge Availability Suite 3.2 User Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
19
CHAPTER
3
Error Messages
Error messages during the installation process are described in the Sun StorEdge
Availability Suite 3.2 Software Installation Guide. Solaris error messages related to the
Sun StorEdge Availability Suite software are described in ....
TABLE 3-1 lists Sun StorEdge Availability Suite 3.2 error messages in alphabetical
order. The error messages come from the following sources:
PITC: From the point-in-time copy software. This software used to be called “Sun
StorEdge Instant Image” software.
RM: From the remote mirror software
Kernel: From the kernel software
Kernel messages might not be printed on the screen but are usually written to
/var/opt/SUNWesm/ds.log or to the system console and recorded in
/var/adm/messages.
TABLE 3-1 Error Messages for the Sun StorEdge Availability Suite 3.2 Software
Error Message From Meaning
'%s' is not a valid number
PITC iiadm was expecting a number to be on the command
line. This happens when the copy parameters option (-
P) is used but the arguments for units and delay are
not valid numbers.
-C <ctag> does not match disk group
PITC iiadm determined that the cluster resource group that
contains the volumes does not match the cluster tag
given as an argument to the -C option.
-C is valid only in a Sun Cluster
PITC The user attempted to specify a cluster tag when not in
a cluster.
Page view 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 51 52

Comments to this Manuals

No comments