Sun Microsystems PCI-X User Manual

Browse online or download User Manual for Servers Sun Microsystems PCI-X. Sun Microsystems PCI-X User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun StorageTek
Enterprise PCI-X
4 Gb FC Single and Dual Port
Emulex Host Bus Adapters
Installation and Basic Interoperability Guide
Part No. 819-5532-12
January 2007, Revision A
Page view 0
1 2 3 4 5 6 ... 67 68

Summary of Contents

Page 1 - Emulex Host Bus Adapters

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun StorageTek™Enterprise PCI-X4 Gb FC Sing

Page 2

x Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Page 3 - Contents

xiPrefaceThis manual describes how to install, configure, and test the Sun StorageTek™Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emu

Page 4

xii Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Using UNIX CommandsThis d

Page 5 - Contents v

Preface xiiiTypographic ConventionsRelated DocumentationThe following documents are available at:http://www.sun.com/products-n-solutions/hardware/docs

Page 6

xiv Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Documentation, Support, a

Page 7

1CHAPTER1Product OverviewThis chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 GbFC Single and Dual Port Emulex HBAs (hencef

Page 8

2 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Single and Dual Port HBA Fe

Page 9

Chapter 1 Product Overview 3Minimum System HardwareRequirementsYour system must have an available PCI or PCI-X 64-bit slot to support these singleand

Page 10

4 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Supported Operating Systems

Page 11 - Dual SG-XPCI2FC-EM4-Z

5CHAPTER2Supported System ConfigurationsThis chapter describes the operating systems, host platforms, storage, andinfrastructure configurations that s

Page 12 - Shell Prompts

PleaseRecycleCopyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, I

Page 13 - Typographic Conventions

6 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Basic InteroperabilityThis

Page 14 - Sun Welcomes Your Comments

Chapter 2 Supported System Configurations 7Storage System SupportThe single and dual port HBAs support the storage systems are listed below. Sun Stor

Page 15 - Product Overview

8 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Solaris 8, 9, and 10 Operat

Page 16 - Feature Description

Chapter 2 Supported System Configurations 9Red Hat Enterprise Linux and SuSELinux Enterprise Server OperatingSystem RequirementsThis section contains

Page 17 - Requirements

10 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Windows 2000 and Windows S

Page 18 - Supported Operating Systems

Chapter 2 Supported System Configurations 11 CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transportfailure for a’timeout’ reas

Page 19

12 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Page 20 - Basic Interoperability

13CHAPTER3Hardware InstallationThis chapter provides instructions for installing the Sun StorageTek Enterprise PCI-X4 Gb FC Single and Dual Port Emule

Page 21 - Fibre Channel Switch Support

14 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Verify the Packaging

Page 22

Chapter 3 Hardware Installation 15FIGURE 3-1 Removing the Bracket Screwsb. Remove the bracket and store it for future use.c. Align the new mounting br

Page 23 - System Requirements

iiiContentsPreface xi1. Product Overview 1Single and Dual Port HBA Features 2Minimum System Hardware Requirements 3Supported Operating Systems 42. Sup

Page 24 - Known Issues and Bugs

16 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007FIGURE 3-2 Installing the

Page 25

Chapter 3 Hardware Installation 17Follow these steps when attaching the optical cable:1. Connect the fiber-optic cable to an LC connector on the dual

Page 26

18 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Apply Power1. Verify

Page 27 - Hardware Installation

Chapter 3 Hardware Installation 19▼ To Verify Proper Installation in SPARCPlatforms1. Enter the show-devs command at the ok prompt to list the install

Page 28 - To Install the HBA Hardware

20 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 20072. To positively identify

Page 29 - Removing the Bracket Screws

Chapter 3 Hardware Installation 21▼ To Verify the Attached Storage● If online storage is connected to the HBA installed in a SPARC system, use theappl

Page 30 - To Attach the Optical Cable

22 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Verify Proper Install

Page 31 - Optical Cable Specifications

23CHAPTER4Software InstallationAfter you have completed the hardware installation and powered on the computer,follow the instructions listed for your

Page 32 - To Apply Power

24 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Page 33 - Platforms

Chapter 4 Software Installation 25The packages and patches are available either bundled as a script posted in the SunDownload Center (SDLC), or as ind

Page 34 - TABLE 3-3

iv Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-3. Hardware Installation 13▼ To Veri

Page 35 - TABLE 3-4

26 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007▼ To Do A Manual Installat

Page 36 - Service Contact Information

Chapter 4 Software Installation 271. Go to http://sunsolve.sun.com.The SunSolve Online license agreement page displays.2. Accept the License Agreement

Page 37 - Software Installation

28 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Downloading HBA Driver Pac

Page 38 - Operating Systems

Chapter 4 Software Installation 29▼ To Download the PatchesPerform the following steps to download the Solaris 10 patches.1. Go to http://sunsolve.sun

Page 39

30 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Page 40 - To Do A Manual Installation

Chapter 4 Software Installation 31Red Hat and SuSE OS Diagnostic SupportDiagnostic support is provided by the Emulex lputil and HBAnyware utilities.Th

Page 41 - Sun Solaris 8 and 9 Patches

32 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Installing the HBA Driver

Page 42 - To Download the Packages

Chapter 4 Software Installation 33▼ To Install the Diagnostic and ManagementUtilitiesDiagnostic support is provided by the Emulex lputil and HBAnyware

Page 43 - Diagnostic Support

34 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Page 44

35APPENDIXADeclaration of Conformity,Regulatory Compliance, and SafetyStatementsThis appendix contains the following information that applies to the S

Page 45 - Creating a Linux Boot Disk

Contents v▼ To Create a Windows Boot Disk 33Service Contact Information 33A. Declaration of Conformity, Regulatory Compliance, and Safety Statements 3

Page 46

36 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Page 47

37Declaration of ConformityEMCUSA—FCC Class AThis equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditio

Page 48

38 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007/S/ /S/Dennis P. Symanski

Page 49 - Statements

39Regulatory Compliance StatementsYour Sun product is marked to indicate its compliance class:• Federal Communications Commission (FCC) — USA• Industr

Page 50

40 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007ICES-003 Class A Notice -

Page 51

Regulatory Compliance Statements 41BSMI Class A NoticeThe following statement is applicable to products shipped to Taiwan and marked as Class A on the

Page 52

42 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007

Page 53 - FCC Class A Parts

43Safety Agency ComplianceStatementRead this section before beginning any procedure. Thefollowing text provides safety precautions to follow wheninsta

Page 54

44 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Power Cord ConnectionCauti

Page 55 - GOST-R Certification Mark

Safety Agency Compliance Statement 45Rack System WarningThe following warnings apply to Racks and Rack Mountedsystems.Caution – For safety, equipment

Page 56

vi Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Page 57 - Statement

46 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007SymbolesVous trouverez ci-

Page 58 - System Unit Cover

Safety Agency Compliance Statement 47Attention – Tous les cordons d'alimentationne présentent pas les mêmes caractéristiquesélectriques. Les cord

Page 59 - Mesures de sécurité

48 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Attention – Afin d'év

Page 60

Safety Agency Compliance Statement 49Je nach Netzschaltertyp an Ihrem Gerät kann eines derfolgenden Symbole verwendet werden:Ein – Versorgt das System

Page 61 - Couvercle de l'unité

50 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Die folgende Warnung gilt

Page 62 - Vorschriften

Safety Agency Compliance Statement 51Hinweis zur Laser-KonformitätSun-Produkte, die die Laser-Technologie verwenden,entsprechen den Laser-Anforderunge

Page 63 - Anschluss des Netzkabels

52 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007Nivel de ruidoDeclared noi

Page 64 - Gehäuseabdeckung

Safety Agency Compliance Statement 53Cubierta de la unidad del sistemaDebe extraer la cubierta de la unidad del sistemainformático Sun para instalar t

Page 65 - Normativas de seguridad

54 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007DanmarkAdvarsel! – Litiumb

Page 66 - Nivel de ruido

viiFiguresFIGURE 3-1 Removing the Bracket Screws 15FIGURE 3-2 Installing the Single and Dual Port HBAs 16FIGURE 3-3 Attaching the Optical Cable 17

Page 67 - Laser Klasse 1

viii Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-

Page 68

ixTablesTABLE 1-1 Single and Dual Port HBA Features 2TABLE 2-1 Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windo

Comments to this Manuals

No comments