Sun-microsystems X6240 User Manual

Browse online or download User Manual for Computers Sun-microsystems X6240. Sun Microsystems X6240 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Blade
X6240
Server Module Installation Guide
Part No. 820-3968-10, Rev. A
June 2008
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - Sun Blade

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun Blade™X6240Server Module Installation G

Page 2

x Sun Blade X6240 Server Module Installation Guide • June 2008Support, and TrainingProduct UpdatesFor product updates that you can download for the Su

Page 3 - Contents

Preface xiSun Welcomes Your CommentsSun is interested in improving its documentation and welcomes your comments andsuggestions. You can submit your co

Page 4

xii Sun Blade X6240 Server Module Installation Guide • June 2008

Page 5 - Contents v

1CHAPTER1Setting Up the Server HardwareThis chapter describes how to insert the Sun Blade X6240 server module into thechassis, how to power on and pow

Page 6

2 Sun Blade X6240 Server Module Installation Guide • June 20082. Connect all cables, peripherals, and power cords to the chassis.See the installation

Page 7 - Using UNIX Commands

Chapter 1 Setting Up the Server Hardware 3▼ To Insert the Server Module1. Locate the desired server module slot in the chassis.2. (Optional) Remove th

Page 8 - Related Documentation

4 Sun Blade X6240 Server Module Installation Guide • June 2008FIGURE 1-1 Inserting the Server Module Into the Chassis4. Push the server module into th

Page 9 - Preface ix

Chapter 1 Setting Up the Server Hardware 5Powering On and Powering Off theServer ModuleYou have to apply only standby power to the server module at th

Page 10 - Third-Party Web Sites

6 Sun Blade X6240 Server Module Installation Guide • June 20082. Use a pointed object or stylus to press and release the recessed Power button onthe s

Page 11 - Sun Welcomes Your Comments

Chapter 1 Setting Up the Server Hardware 7▼ To Shut Down Main Power ModeTo power off the server module from main power mode, use one of the following

Page 12

PleaseRecycleCopyright © 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,

Page 13

8 Sun Blade X6240 Server Module Installation Guide • June 2008Using a Dongle Cable for TestingYour chassis ships with a dongle cable. The dongle enabl

Page 14 - Inserting the Server Module

Chapter 1 Setting Up the Server Hardware 9FIGURE 1-3 Dongle Cable ConnectionsLegendConnector Status1 Dual USB 2.0 connectors Used2 Serial port connect

Page 15 - ▼ To Insert the Server Module

10 Sun Blade X6240 Server Module Installation Guide • June 2008

Page 16 - FIGURE 1-1

11CHAPTER2Setting Up the Server SoftwareThis chapter describes how to configure and access the Sun™Integrated Lights OutManager software, and how to s

Page 17 - Server Module

12 Sun Blade X6240 Server Module Installation Guide • June 2008Note – This chapter describes how to access ILOM through the command-lineinterface and

Page 18

Chapter 2 Setting Up the Server Software 13Note – The CMM ILOM is shipped with an identical preconfigured Administratoraccount, with user name root an

Page 19

14 Sun Blade X6240 Server Module Installation Guide • June 2008Note – Option 1 and option 2 enable you to connect to ILOM without knowingILOM’s IP add

Page 20 - FIGURE 1-3

Chapter 2 Setting Up the Server Software 152. Configure the terminal device or the terminal emulation software to use thefollowing settings: 8N1: eig

Page 21 - Dongle Cable Connections

16 Sun Blade X6240 Server Module Installation Guide • June 20085. Log in to the CLI:a. Type the default user name, root.b. Type the default password,

Page 22

Chapter 2 Setting Up the Server Software 17The following display shows an example of the login screen.-> cd /CH/BL2/SP/cli/CH/BL2/SP/cli-> start

Page 23 - Integrated Lights Out Manager

iiiContentsPreface vii1. Setting Up the Server Hardware 1Installation Overview and Terms 1Inserting the Server Module 2▼ To Insert the Server Module 3

Page 24 - What Is a Service Processor?

18 Sun Blade X6240 Server Module Installation Guide • June 2008Option 2: Connecting to ILOM Through a DongleCableYou can use the dongle cable to conne

Page 25 - ILOM Connection Overview

Chapter 2 Setting Up the Server Software 19Legend▼ To Connect to ILOM Using a Dongle Cable1. Connect a dongle cable to the server module.2. Connect a

Page 26 - Chassis Serial Connector

20 Sun Blade X6240 Server Module Installation Guide • June 2008Logging In and Out of ILOMYou can use either the ILOM command-line interface (CLI) or w

Page 27 - TABLE 2-1

Chapter 2 Setting Up the Server Software 21FIGURE 2-3 Web GUI ILOM Login Screen2. Type your user name and password.When you first try to access the we

Page 28

22 Sun Blade X6240 Server Module Installation Guide • June 2008FIGURE 2-4 ILOM Log Out Screen

Page 29 - -> cd /CH/BL2/SP/cli

Chapter 2 Setting Up the Server Software 23Configuring the ILOM IP AddressThis section describes how to view and set the ILOM IP address. It includes

Page 30 - Dongle Cable

24 Sun Blade X6240 Server Module Installation Guide • June 2008c. After you see the message, press F2.After some messages and screen changes, the BIOS

Page 31 - Ethernet Port

Chapter 2 Setting Up the Server Software 25▼ To Configure the ILOM IP Address Using DHCPThis procedure uses DHCP to assign ILOM an IP address.1. Verif

Page 32 - Logging In and Out of ILOM

26 Sun Blade X6240 Server Module Installation Guide • June 2008b. Type the reset command:-> reset /SPDHCP automatically assigns ILOM an IP address

Page 33 - Web GUI ILOM Login Screen

Chapter 2 Setting Up the Server Software 274. Do one of the following: To configure a static Ethernet configuration, type the following commands:->

Page 34 - ILOM Log Out Screen

iv Sun Blade X6240 Server Module Installation Guide • June 2008Option 1: Connecting to ILOM Through the Chassis Serial Connector 14▼ To Connect to ILO

Page 35 - ▼ To View the ILOM IP Address

28 Sun Blade X6240 Server Module Installation Guide • June 2008-> cd /SP/network-> show/SP/network Targets: Properties: commitpending

Page 36 - ■ Look in the DHCP log file

Chapter 2 Setting Up the Server Software 29Setting Up Platform Operating Systemand Driver SoftwareAfter configuring the server module ILOM network set

Page 37

30 Sun Blade X6240 Server Module Installation Guide • June 2008

Page 38

31CHAPTER3Configuring the PreinstalledSolaris 10 Operating SystemThis chapter explains the steps for configuring the Solaris™10 Operating System(OS) t

Page 39

32 Sun Blade X6240 Server Module Installation Guide • June 2008Before You BeginBefore you begin configuring the preinstalled Solaris 10 OS, do the fol

Page 40

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 33TABLE 3-1 Worksheet for Solaris 10 ConfigurationInformation for Installation Desc

Page 41

34 Sun Blade X6240 Server Module Installation Guide • June 2008Name service Name service If applicable, which name service should thissystem use?• NIS

Page 42

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 35Default route Do you want to specify a default route IP address,or let the Solari

Page 43 - Solaris 10 Operating System

36 Sun Blade X6240 Server Module Installation Guide • June 2008Configuring the Preinstalled Solaris 10Operating SystemNote – Before you perform this p

Page 44 - Before You Begin

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 372. Verify that the communication properties of the service processor are set to t

Page 45 - Defaults (*)

Contents vSolaris 10 Operating System User Information 43Solaris 10 User Documentation 43Solaris 10 OS Training 44Using the Solaris Installation Progr

Page 46

38 Sun Blade X6240 Server Module Installation Guide • June 2008▼ To Redirect the Console Output to the VideoPort (Optional)The server module’s console

Page 47 - from GM

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 39Configuring X6240 Server Module RAIDDrivesAfter you configure the Solaris OS, you

Page 48 - Operating System

40 Sun Blade X6240 Server Module Installation Guide • June 2008RAID Drive OptionsTABLE 3-3 shows the RAID drive options.TABLE 3-3 RAID Drive OptionsMi

Page 49

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 41If you choose the preinstalled Solaris OS and want to make the OS part of a RAIDs

Page 50 - Port (Optional)

42 Sun Blade X6240 Server Module Installation Guide • June 2008Creating a RAID Set to Incorporate aPreinstalled OS Using the SunStorageTek REM CardThe

Page 51 - RAID Drive Overview

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 438. Click the screen to activate the Managed Systems List.9. Double-click the loca

Page 52 - RAID Drive Options

44 Sun Blade X6240 Server Module Installation Guide • June 2008Solaris 10 OS TrainingSun provides flexible training options that accommodate your pers

Page 53 - Solaris OS

Chapter 3 Configuring the Preinstalled Solaris 10 Operating System 45application performance analysis and debugging of mixed source languageapplicatio

Page 54 - StorageTek REM Card

46 Sun Blade X6240 Server Module Installation Guide • June 2008

Page 55 - Information

47CHAPTER4Configuring the PreinstalledMicrosoft Windows Server 2003 R2Operating SystemThis chapter describes how to complete the intial setup of the p

Page 56 - Sun Studio 11

vi Sun Blade X6240 Server Module Installation Guide • June 2008

Page 57 - Downloading Software

48 Sun Blade X6240 Server Module Installation Guide • June 2008Before You BeginBefore you begin the initial setup of the preinstalled Windows Server 2

Page 58

Chapter 4 Configuring the Preinstalled Microsoft Windows Server 2003 R2 Operating System 49For additional information about which console option to se

Page 59

50 Sun Blade X6240 Server Module Installation Guide • June 20083. In the Welcome to Windows Setup dialog, click Next and continue the setupprocess by

Page 60

Chapter 4 Configuring the Preinstalled Microsoft Windows Server 2003 R2 Operating System 51RAID Drive OverviewThe Sun Blade X6240 server module has tw

Page 61 - Server 2003 R2 OS

52 Sun Blade X6240 Server Module Installation Guide • June 2008RAID Drive OptionsTABLE 4-2 shows the RAID drive options.TABLE 4-2 RAID Drive OptionsMi

Page 62

Chapter 4 Configuring the Preinstalled Microsoft Windows Server 2003 R2 Operating System 53If you choose the preinstalled Windows Server 2003 R2 OS an

Page 63

54 Sun Blade X6240 Server Module Installation Guide • June 2008Creating a RAID Set to Incorporate aPreinstalled OS Using the SunStorageTek REM CardThe

Page 64

Chapter 4 Configuring the Preinstalled Microsoft Windows Server 2003 R2 Operating System 556. Click on the SUN STK RAID Controller.All attached hard d

Page 65 - Windows OS

56 Sun Blade X6240 Server Module Installation Guide • June 2008Important InformationAfter completing the Windows setup, refer to these sections about

Page 66

Chapter 4 Configuring the Preinstalled Microsoft Windows Server 2003 R2 Operating System 57FIGURE 4-2 Sun Supplemental SoftwareRecovery Media KitIf yo

Page 67

viiPrefaceThis Sun Blade X6240 Server Module Installation Guide contains procedures forinstalling the server module in a chassis, connecting to the se

Page 68 - Important Information

58 Sun Blade X6240 Server Module Installation Guide • June 2008

Page 69 - Recovery Media Kit

59IndexCchassis management module (CMM) ILOM, 12chassis management module see CMMchassis, defined, 1CMM, defined, 1command line interface (CLI)SSH log i

Page 70

60 Sun Blade X6240 Server Module Installation Guide • June 2008Ppassword, root, 20PCI EM MAC address, 32powerpowering off, 7powering on standby power,

Page 71

viii Sun Blade X6240 Server Module Installation Guide • June 2008Shell PromptsTypographic ConventionsRelated DocumentationThe documents listed in the

Page 72

Preface ixNote – The last two digits of the documentation part number identify the latestversion of the product documentation that is available for do

Comments to this Manuals

No comments